Digital display meter 0-10V 0-20mA 2-10V 4-20mA analog input display table Digital display head

€ 36,95
+ € 17,99 Verzending

Digital display meter 0-10V 0-20mA 2-10V 4-20mA analog input display table Digital display head

  • Merk: Unbranded
Verkocht door:

Digital display meter 0-10V 0-20mA 2-10V 4-20mA analog input display table Digital display head

  • Merk: Unbranded
Adviesprijs: € 48,95
Prijs: € 36,95
Je bespaart: € 12,00 (24%)
Verkocht door:
€ 36,95
+ € 17,99 Verzending

Op voorraad

We accepteren de volgende betalingsmethoden

Beschrijving

1. The meter can be called a universal analog input display meter. It can be matched with various sensors with analog output to display the actual physical quantity. Such as temperature transmitter, frequency converter, motor speed, preure, liquid level, concentration, etc. 2. The instrument supports current input or voltage input. 3. Default adaptation: 0-10V, 2-10V, 0-20mA, 4-20mA. By setting the bias parameter and gain parameter, it can adapt to other inputs in the range of 0-10V, or 0-20mA. 4. It is displayed as a percentage by default. You can also set your own display range through F0-2 ~ F0-4. 5. The instrument with 485 interface has already supported the communication between the meters, and it is convenient to realize multiple displays. Main features Model description,standard version: HXDSBOXAI-NR;With RS485 version: HXDSBOXAI-485;With relay output version: HXDSBOXAI-RL Standard version and version with RS485, rated power supply voltage range: DC6~25V, power consumption: 24V/40mA;with relay output version, rated power supply voltage Range: DC8~25V, powerconsumption: 24V/50mA;power supply anti-reverse connection and surge protection 1 analog input, voltage type or current type can be selected Voltage type input impedance: >30kQ, current type input impedance: "With RS485 version", using standard Modbus-RTU protocol, easy to achieve networking: and support networking between tables,"With relay output version", with 1 normally open relay output, relay load capacity: 3A30Dc/3A250VAC; Mechanical size: 794325mm: installation opening: 76.539.5mm. Indicator light and signal description 1.Front panel diagram 2. Indicator light: a. Only "with RS485 version" is useful: R communication receives data indication: T communication sends data indication b. Only the "with relay output version" has: S indicator light on when the relay is closed 3.Port signal description signal Explanation PWR Connectto the positive pole of the power supply (standard version and versionwith RS485: DC6~30V: with relay output version: DC8~30V) GND Power and signal ground Ai Power and signal ground mA Current-type analog input signal configuration interface, short-circuited with A, then configured as current-type input WithRS485 version 485- RS485 signal is negative 485+ RS485 signal is positive With relay outputversion KA Relay normally open contact output port KB 4.Common wiring diagram: 5. Button and digital tube display state transition diagram: Special note: In the third-level menu, click OK to save the modified parameter value and return to the previous menu, the parameter number is automatically increased by one; and click the SET button to directly return to the previous menu without saving the modified parameter value .Long pre or to make the adjustment value change quickly. Parameter description The parameters are described as follows: 1.F0 Attendant array display Parameter parameter name Scope and description Defaults Read write F0-0 Collected value monitoring Monitor the percentage of the current analog input value. Range: 0-100.0% read-only F0-1 Display value monitoring In the display value in "Monitoring Menu" is calculated by F0-0, F0-2~F04. read-only F0-2 Display accuracy The number of decimal places displayed in the "Monitor Menu", range: 0-3. 1 Read write F0-3 Show minimum In the "monitoring menu", the value corresponding to "acquisition value" is 0%, the range: -1999~9999 0 Read write F0-4 Show maximum In the "Monitoring Menu", the value corresponding to the "Acquisition Value" is 100.0%, the range: 1999~9999 1000 Read write F0-5 Offline status 0: Not disconnected; 1: Disconnected. (Disconnection detection is set by F1-4) (starting from V2.10) read-only 2.F1 parameter group-analog configuration parameters Parameter parameter name Scope and description Defaults Read write F1-0 Input type selection 0: 0~10V or 0~20mA corresponds to 0~100.0%; 1: 2~10V or 4~20mA corresponds to 0~100.0%, and 0 when it is lower than 2V or 4mA. 0 Read write F1-1 Input filter time Analog input filter time, range: 0~10.000s. The longer the filtering time, the stronger the filtering 0.200 Read write F1-2 Input gain Range: 0~1000.0%. 100.0 Read write F1-3 Input offset -99.9~99.9%, with 10V or 20mA as 100.0%. 0.0 Read write F1-4 Drop detection threshold Range: 0.0-100.0%. This value is based on 0-10V or 0-20mA as 0.0-100.0% as a reference (and F1-0 and gain offset are not related), the detection is not started if it is le than 0.5, and there is a hysteresis of 0.3. When the input signal is lower than this value, the meter displays E.oFL. (Starting from V2.10) 0.0 Read write F1-5 Enter the parameter setting select
  • Fruugo-ID: 279403132-621274316
  • EAN: 9085801629309

Productveiligheidsinformatie

Raadpleeg de onderstaande productveiligheidsinformatie die specifiek is voor dit product

De volgende informatie wordt verstrekt door de onafhankelijke externe detailhandelaar die dit product verkoopt.

Productveiligheidslabels

CE Mark
Veiligheidswaarschuwingen:
  • Keep out of reach of children: Prevent accidental ingestion, misuse, or harm.
  • Always follow instructions: Ensures proper usage and prevents malfunctions or accidents.

Levering & retouren

Wordt binnen 24 uur verzonden

  • STANDARD: € 17,99 - Levering tussen do 16 oktober 2025–vr 24 oktober 2025

Verzending vanaf China.

We doen ons best om ervoor te zorgen dat de producten die u bestelt volledig en volgens uw specificaties bij u worden afgeleverd. Mocht u echter een onvolledige bestelling ontvangen of andere artikelen dan degene die u heeft besteld, of als er een andere reden is waarom u niet tevreden bent met de bestelling, dan kunt u de bestelling retourneren, of welk product dan ook die bij de bestelling was inbegrepen, en ontvangt u een volledige terugbetaling voor de artikelen. Bekijk het volledige retourbeleid

Productconformiteitsdetails

Raadpleeg de onderstaande nalevingsinformatie die specifiek is voor dit product.

De volgende informatie wordt verstrekt door de onafhankelijke externe detailhandelaar die dit product verkoopt.

Fabrikant:
Hieronder treft u de contactgegevens van de fabrikant van het betreffende product dat op Fruugo wordt verkocht.

  • Shenzhenshi Sinizefushi Youxiangongsi
  • Shenzhenshi Sinizefushi Youxiangongsi
  • 606, Mingcheng International Plaza, Longgang Avenue, Maoye community,
  • Buji street, Longgang District
  • Shenzhen
  • CN
  • 518000
  • alitianmei@163.com
  • 13265018442

Verantwoordelijke persoon in de EU:
De volgende informatie bevat de contactgegevens van de verantwoordelijke persoon in de EU. De verantwoordelijke persoon is de aangewezen marktdeelnemer in de EU, die verantwoordelijk is voor de nalevingsvereisten met betrekking tot het product dat in de Europese Unie verkocht wordt.

  • JUAN SERRANO GONZALEZ SOCIEDAD LIMITADA
  • JUAN SERRANO GONZALEZ SOCIEDAD LIMITADA
  • C/PABLO IGLESIAS 1-A-ENTRESUELO
  • CASTELLON DE LA PLANA
  • Spain
  • 12006
  • alitianmei@163.com
  • 0034 964 867178