GM328A Transistor Diode LCD Tester LCR Capacitance ESR Voltage Frequency Meter PWM Square Wave Signal Generator Electronic Kits

34,95 €
+ 11,99 € Versand

GM328A Transistor Diode LCD Tester LCR Capacitance ESR Voltage Frequency Meter PWM Square Wave Signal Generator Electronic Kits

  • Marke: Unbranded

GM328A Transistor Diode LCD Tester LCR Capacitance ESR Voltage Frequency Meter PWM Square Wave Signal Generator Electronic Kits

  • Marke: Unbranded
UPE: 149,00 €
Preis: 34,95 €
Sie sparen: 114,05 € (76%)
Verkauft von:
34,95 €
+ 11,99 € Versand

Auf Lager

Wir akzeptieren die folgenden Zahlungsmethoden

Beschreibung

GM328A Transistor Diode LCD Tester LCR Capacitance ESR Voltage Frequency Meter PWM Square Wave Signal Generator Electronic Kits Note: Some features are not available in the Russian version, please choose to purchase according to your needs~! Product parameters Input voltage: Type -C DC5V Self welding: DC 9V connector (DC 9V: requires self welding of connectors before use) Operating voltage: 30mA approx. Transistor tester control 1.The tester is controlled by a rotary encoder switch. 2.The rotary encoder switch can be operated in a total of 6 ways, short press, long press, left turn, right turn, press and hold left turn, press and hold right turn. 3.A short press in the off position turns the power on and starts the test. 4.After a test has been completed, if no device is detected. Press and hold the switch or rotate the switch left or right to enter the function menu. Once in the function menu, the left or right switch can be rotated up or down through the menu items, to enter a particular function item, press the switch once short. When it is necessary to exit from a certain function, then press the switch long. Test Devices The tester has 3 test points, TP1, TP2 and TP3, which are distributed in the test stand as follows On the right hand side of the test stand are the test positions for the SMD components, with the numbers 1,2,3, each representing TP1, TP2 and TP3 respectively. When testing components with only 2 pins, the pins are not divided into test order, 2 pins are chosen for any 2 test points, and the pins of 3-pin devices are placed in three test points, in no particular order. After the test, the tester automatically recognises the pin name of the component, the test point where it is located and displays it on the screen. When testing components with only 2 pins, if two test points are used, TP1 and TP3, the tester automatically enters continuous test mode after the test is completed, so that the components on TP1 and TP3 can be measured continuously and simultaneously without having to press the switch again. If "TP1 and TP2" or "TP2 and TP3" are used, only one test is performed. To test again, press the switch once. Note: Before testing the capacitor, discharge the capacitor before inserting it into the test holder for measurement, otherwise there is a risk of damaging the tester's microcontroller. 1,Calibration The tester calibration is used to eliminate errors in its own components, making the final test results more accurate. Calibration is divided into quick calibration and full function calibration. The operation method for quick calibration: short the three test points TP1, TP2 and TP3 with wires and then press the test button while watching the screen. The screen colour will change to white text on a black background. After the prompt message "Selftest mode...? ", press the test button to enter the fast calibration process; if, after the message "Selftest mode...? If no button is pressed within 2 seconds after the message "Selftest mode...", the normal test process is carried out and the resistance values of the three test points TP1, TP2 and TP3 are displayed at the end. After entering the quick calibration process, some data will appear on the screen, ignore it. Wait until a flashing string appears on the screen After "isolate Probes!", remove the shorted TP1, TP2 and TP3 leads. The quick calibration is complete until the string "Test End" appears on the screen. When calibrating for the first time, use the full function calibration method. The full function calibration is accessed from the function menu and requires an additional 220nf capacitor. Full function calibration performs a more comprehensive calibration process and can take longer. Once in the function menu, turn the test button to the menu item "Selftest", then press the test button to enter the full function calibration process, which starts with the flashing string "short Probes! When the flashing string "isolate Probes!" appears on the screen, remove the wires from the three test points and continue to wait for the calibration process to proceed, when the string "1-||- 3 > 100nf", install the prepared 220nf capacitors on test points TP1 and TP3. Wait until the screen says "Test End" and the fully functional calibration process is complete. 2. Function menu 2.1 Switch off 2.2 Transistor 2.3 Frequency Measures the frequency. Press and hold the test button to exit the frequency measurement function. The frequency measurement range is from 1 Hz to more than 1 MHz, when the measured frequency is below 25 KHz, the period is displayed 2.4 f-Generator Square wave generator with multiple square wave frequencies selectable, turn the test button left or right to switch between different square wave frequencies, long press the test button to exit the square wave generator. 2.5 10-bit PWM Pulse generator, left or right turn the test
  • Fruugo-ID: 405876432-860618363
  • EAN: 7617000533532

Produktsicherheitsinformationen

Bitte beachten Sie die unten aufgeführten spezifischen Produktsicherheitsinformationen für dieses Produkt

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Produktsicherheitsetiketten

CE Mark
Sicherheitswarnungen: WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
Zutaten: Octinoxate 5.2867%
Teilenummer des Herstellers: JK203027
Modellnummer: JK199930
Seriennummer: JK062427
Chargennummer: JK197038

Lieferung und Rückgaben

Versand innerhalb von 3 Tagen

  • EXPRESS: 11,99 € - Lieferung zwischen Mo. 06 Oktober 2025–Mi. 15 Oktober 2025

Versand von China.

Wir tun unser Bestes, um dafür zu sorgen, dass die von Ihnen bestellten Produkte vollständig und gemäß Ihrer Spezifikationen an Sie geliefert werden. Wenn Sie allerdings eine unvollständige Bestellung oder Artikel erhalten, die sich von den bestellten unterscheiden, oder es einen anderen Grund gibt, warum Sie mit Ihrer Bestellung nicht zufrieden sind, können Sie die gesamte Bestellung oder einzelne darin enthaltenen Produkte zurücksenden und eine vollständige Rückerstattung für die Artikel erhalten. Vollständige Rückgaberichtlinie ansehen

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Hersteller:
Es folgen die Kontaktdaten für den Hersteller des jeweiligen Produkts, das auf Fruugo verkauft wird.

  • UMCU
  • shenzhenshixiangpulitiankejiyouxiangongsi
  • 301 (308), No. 32, Xiangyin Road, Nanlian Community, Longgang Street, Longgang District
  • Shenzhen
  • China
  • 518000
  • teuneva@126.com
  • 13535306199
  • https://www.fruugo.co.uk/umcu/m-17124?language=en

Verantwortliche Person in der EU:
Es folgen die Kontaktinformationen für die verantwortliche Person in der EU. Die verantwortliche Person ist der benannte Wirtschaftsteilnehmer mit Sitz in der EU und verantwortlich für die Compliance-Verpflichtungen in Verbindung mit dem jeweiligen Produkt, das in die Europäische Union verkauft wird.

  • EC REP SERVICES SL
  • EC REP SERVICES SL
  • Calle Gran Via 49, 7 DCH.
  • Madrid
  • Spain
  • 28013
  • ecrepservice@hotmail.com
  • 34682797075