FV-3KHz10V Frequency Voltage Converter Module 0~3Khz to 0~10V Digital to Analog Signal Module

16,93 €
la livraison GRATUITE

FV-3KHz10V Frequency Voltage Converter Module 0~3Khz to 0~10V Digital to Analog Signal Module

  • Marque: Unbranded
Verkocht door:

FV-3KHz10V Frequency Voltage Converter Module 0~3Khz to 0~10V Digital to Analog Signal Module

  • Marque: Unbranded
Prix de vente conseillé : 29,03 €
Prix : 16,93 €
Vous économisez : 12,10 € (41%)
Verkocht door:
16,93 €
la livraison GRATUITE

En stock

Nous acceptons les modes de paiement suivants

Description

Features 1、The 0-3KHz frequency pulse signal is converted into a 0-10V analog voltage signal by this module. 2、The module can be used for interface conversion between PLC and frequency converter or matching control of interface between motion control card and frequency converter. 3、Input pulse level of 5V 12V 24V can be input directly without string resistance.But the input signal frequency, to maintain more than 0.5 seconds, the output current is 5mA. 4、The multi-coil potentiometer on the board is used to calibrate the corresponding relationship between frequency and voltage. 5、The optical isolate is used to ensure the anti-interference ability of the signal input. Specification Features: The module can be used for interface conversion between PLC and frequency converter or matching control of interface between motion control card and frequency converter. Input pulse level of 5V 12V 24V can be input directly without string resistance.But the input signal frequency, to maintain more than 0.5 seconds, the output current is 5mA. The optical isolate is used to ensure the anti-interference ability of the signal input. Specification: Size:4.5 x 4.7 x 1.7cm / 1.77 x 1.85 x 0.67in Relationship,Linearity: 300Hz to 1V 1.5Khz to 5V 3Khz to 10V Package List: 1 x Converter Module Note: For use with PLC, support for NPN type. Must have a ground wire. If you need to use an encoder, you need to keep the encoder running at a constant speed for more than 0.5 seconds. If the signal input is turbine flow, etc., due to signal matching, an 817 diaphragm and a resistor must be added to match the flowmeter to function properly. If there is a deviation in the correspondence when using, you can adjust the blue potentiometer on the board to calibrate. At the time of shipment, we have adjusted the F/V potentiometer to a certain correspondence. It is generally not recommended to adjust it by itself. Package List
  • Identifiant Fruugo: 271639001-602151488
  • EAN: 9308869116605

Informations sur la sécurité des produits

Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Étiquettes de sécurité des produits

CE Mark
Avertissements de sécurité: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

Livraison & retours

Expédition dans un délai de 2 jours

  • STANDARD: GRATUIT - Livraison entre lun. 13 octobre 2025–ven. 17 octobre 2025 - GRATUIT

Expédition de Chine.

Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour